Key Points

  • Initial site review and hazard analysis
  • Comprehensive pre-construction information documentation
  • Notification of the project to HSE
  • Assistance with development of the construction phase plan
  • Formal review prior to construction phase
  • Review of project’s health and safety file prior and issued to the client in accordance with CDM2015

Client Requirement

In 2012, Callidus were selected as the sole-supplier of CDM-related compliance services for ASDA as part of a two year framework agreement. The The Britannia House refurbishment project involved the complete strip out to an existing office/laboratories building to be converted to office accommodation.

The scope of the work to phase 1 included complete strip out of the building including mechanical and electrical installations, laboratories, fixtures and fittings and windows and refitting the ground floor as office accommodation with meeting rooms. Installation of new external steel fire escape stair, with new openings formed and fire doors fitted.

Service
CDM Coordinator

Sector
Retail

Project
Britannia House Refurbishment

Our Solution

As part of our role, Callidus carried out a review of the proposed design and produced a pre-construction information document and hazard register. This was then communicated to all project team members, stakeholders and proposed contractors via an online portal.

The project was notified to HSE and the Principal Contractor’s construction phase plan was formally reviewed prior to being accepted in time to allow the construction phase to commence as planned.

Benefits of using Callidus

Having worked with the design team members previously on numerous ASDA projects, Callidus had developed good, strong working relationships with each supplier. Our consultants have an excellent track record of working in collaboration with other businesses and are able to add extensive industry experience to each commission.

For the Britannia House project, Callidus also advised on the procurement of further surveys and investigations that were required as part of the PCI preparation process. This included the appointment of a specialist chemical analyst to undertake bacterial testing of the drainage systems and fume cupboard extract due to the building’s previous use as an NHS Trust’s Pathology Department.